Transport gratuit la punctele de livrare Pick Up peste 299 lei
Packeta 15 lei Easybox 20 lei Cargus 25 lei FAN 25 lei

Tube Failures in Pulverised Coal Fired Boilers: An Investigation

Limba englezăengleză
Carte Carte broșată
Carte Tube Failures in Pulverised Coal Fired Boilers: An Investigation Manoj Mittal
Codul Libristo: 15799062
Editura LAP Lambert Academic Publishing, noiembrie 2016
High temperature corrosion problem in coal based thermal power plants has been matters of concern si... Descrierea completă
? points 119 b
265 lei -9 %
239 lei
În depozitul extern Expediem în 8-10 zile

30 de zile pentru retur bunuri


Ar putea de asemenea, să te intereseze


Realismo y experiencia / Carte broșată
common.buy 87 lei
Interplanetary Mission Analysis and Design Stephen Kemble / Carte broșată
common.buy 1.269 lei
Uydurulmus Sibel Karaca / Carte broșată
common.buy 41 lei

High temperature corrosion problem in coal based thermal power plants has been matters of concern since the very early days of using the combustion of coals to raise steam to generate electricity. The problems could be separated into water wall corrosion, typically at temperatures in the range 350-450?C and super-heater and re-heater corrosion, typically at metal temperatures in the range of 500-650?C. Boiler tubes of coal fired thermal power plant subjected to prolong exposure at elevated temperature loose their load bearing capacity. The corrosion damage at inner and outer surface is responsible for reduction in wall thickness. In service water tubes from FBC boiler after a service life of ten years were collected. Failed tubes from FBC boilers were thoroughly investigated by visual inspection, cross-section and axial measurement, micrography and identification and characteristics of scale by XRD analysis to find the cause of failure. Main cause of failure was found to be corrosion with Fe2O3 as the main corrosion product. Other causes of boiler tube failure were short term overheating, erosion, decomposition of perlite into ferrite.

Informații despre carte

Titlu complet Tube Failures in Pulverised Coal Fired Boilers: An Investigation
Autor Manoj Mittal
Limba engleză
Legare Carte - Carte broșată
Data publicării 2017
Număr pagini 96
EAN 9783659789304
Codul Libristo 15799062
Greutatea 161
Dimensiuni 150 x 220 x 6
Dăruiește această carte chiar astăzi
Este foarte ușor
1 Adaugă cartea în coș și selectează Livrează ca un cadou 2 Îți vom trimite un voucher în schimb 3 Cartea va ajunge direct la adresa destinatarului

Logare

Conectare la contul de utilizator Încă nu ai un cont Libristo? Crează acum!

 
obligatoriu
obligatoriu

Nu ai un cont? Beneficii cu contul Libristo!

Datorită contului Libristo, vei avea totul sub control.

Creare cont Libristo