Transport gratuit la punctele de livrare Pick Up peste 299 lei
Packeta 15 lei Easybox 20 lei Cargus 25 lei FAN 25 lei

Thermal conductivity scanner (TCS)

Limba englezăengleză
Carte Carte broșată
Carte Thermal conductivity scanner (TCS) Amalia Aventurin
Codul Libristo: 02662211
Editura Grin Publishing, aprilie 2014
Internship Report from the year 2013 in the subject Geography / Earth Science - Miscellaneous, grade... Descrierea completă
? points 99 b
200 lei
În depozitul extern Expediem în 14-18 zile

30 de zile pentru retur bunuri


Ar putea de asemenea, să te intereseze


reduceri
Dream Raven Tarot Beth Seilonen / Carte broșată
common.buy 136 lei
Pleasure of a Dark Prince Kresley Cole / Carte broșată
common.buy 59 lei
Pound a Day Diet Rocco Dispirito / Copertă tare
common.buy 115 lei
Slovensko v treťom tisícročí Vladimír Bárta / Copertă tare
common.buy 270 lei
curând
Dukkha Reverb Loren W. Christensen / Carte broșată
common.buy 65 lei
Travels in Arabia Johann Ludwig Burckhardt / Copertă tare
common.buy 416 lei

Internship Report from the year 2013 in the subject Geography / Earth Science - Miscellaneous, grade: 2,0, RWTH Aachen University (Lehrstuhl für Geologie, Geochemie und Lagerstätten des Erdöls und der Kohle), course: Petrophysics Practical Course, language: English, abstract: The thermal conductivity scanner (or TCS) measures the thermal conductivity (W/m K) via optical scanning method. In Figure 1 is a picture of the measurement shown. The thermal conductivity is a material property. High values are used for cooling systems to transport heat away from the material in a short time (e.g. fringes); low values are used as insulators, e.g. thermos flasks. With this method the heater and the detectors where moved along the sample from the right to the left. A sensor measures within the moving first the cold conductivity of the sample. Than the heater follows and a last sensor measures after the heating of 25°C the conductivity of the sample again. Before and after the sample are two reference sources laid with a defined thermal conductivity. These reference sources are need for the sensor calibration, too. To avoid errors there has always to be a gap of a few centimeters between the reference blocks and the measured sample. For the measuring the samples and the reference sources have to be colored with a thick black line to avoid overheating and reflection by lighter samples. The opening has to be covered completely by the painted part of the sample. To control this was a mirror underneath the apparatus. [...]

Informații despre carte

Titlu complet Thermal conductivity scanner (TCS)
Limba engleză
Legare Carte - Carte broșată
Data publicării 2014
Număr pagini 20
EAN 9783656644811
ISBN 3656644810
Codul Libristo 02662211
Editura Grin Publishing
Greutatea 54
Dimensiuni 178 x 254 x 1
Dăruiește această carte chiar astăzi
Este foarte ușor
1 Adaugă cartea în coș și selectează Livrează ca un cadou 2 Îți vom trimite un voucher în schimb 3 Cartea va ajunge direct la adresa destinatarului

Logare

Conectare la contul de utilizator Încă nu ai un cont Libristo? Crează acum!

 
obligatoriu
obligatoriu

Nu ai un cont? Beneficii cu contul Libristo!

Datorită contului Libristo, vei avea totul sub control.

Creare cont Libristo