Transport gratuit la punctele de livrare Pick Up peste 299 lei
Packeta 15 lei Easybox 20 lei Cargus 25 lei FAN 25 lei

New Fluorescent Optical pH Sensors with Minimal Effects of Ionic Strength

Limba englezăengleză
Carte Carte broșată
Carte New Fluorescent Optical pH Sensors with Minimal Effects of Ionic Strength Bernhard Weidgans
Codul Libristo: 04336155
Editura VDM Verlag Dr. Mueller E.K., aprilie 2008
There is still a lack of commercial applications of pH sensors due to the decisive disadvantage that... Descrierea completă
? points 173 b
348 lei
În depozitul extern Expediem în 14-18 zile

30 de zile pentru retur bunuri


Ar putea de asemenea, să te intereseze


Details Limbo / Audio CD
common.buy 44 lei
Cyber Security Culture David Upton / Copertă tare
common.buy 1.070 lei
Marine Air Ground Task Force (MAGTF) Plans Training and Readiness (T&R) Manual U S Marine Corp Department of the Navy / Carte broșată
common.buy 109 lei
Crosby Curiosities Michael Stammers / Carte broșată
common.buy 81 lei
Trees, Shrubs & Hedges for Your Home Editors of Creative Homeowner / Carte broșată
common.buy 106 lei
Rafael Vinoly Architects Rafael Vinoly / Copertă tare
common.buy 655 lei
Spartacus M J Trow / Copertă tare
common.buy 123 lei
Immortal Silence: A Guardians of Dacia Novel Loni Lynne / Carte broșată
common.buy 109 lei
Civic Conversations of Thucydides and Plato Gerald M. Mara / Carte broșată
common.buy 240 lei
New Jersey's Palisades Interstate Park E. Emory Davis / Carte broșată
common.buy 116 lei
Flora Thompson Gillian Lindsay / Carte broșată
common.buy 86 lei

There is still a lack of commercial applications of pH sensors due to the decisive disadvantage that the signal is depending on the ionic strength of the sample. pH is defined as the negative logarithm of the activity of protons in aqueous solution, while the optical parameter (e.g. change of absorption or fluorescence) correlates with the concentration of the pH-sensitive dye. The cross-sensitivity of the calibration curve towards ionic strength can cause pH errors of up to 1.5 pH units. Since the electrolyte concentration, respectively the ionic strength, is not constant in most real samples, optical pH sensors have not often been applied in these systems. In systems with constant ionic strength (e.g. blood, sea water) pH was successfully determined via optical sensors. Therefore, there is a need for optical sensors displaying a comparably negligible effect of ionic strength on the measured signal. This work describes the fabrication and application of fluorescent pH sensors with special attention to minimize of the effect of ionic strength on the sensor. The book is written for students, scientists and people interested in the problems of measuring pH with optical sensors.

Informații despre carte

Titlu complet New Fluorescent Optical pH Sensors with Minimal Effects of Ionic Strength
Limba engleză
Legare Carte - Carte broșată
Data publicării 2008
Număr pagini 144
EAN 9783836491426
ISBN 3836491427
Codul Libristo 04336155
Greutatea 200
Dimensiuni 152 x 229 x 8
Dăruiește această carte chiar astăzi
Este foarte ușor
1 Adaugă cartea în coș și selectează Livrează ca un cadou 2 Îți vom trimite un voucher în schimb 3 Cartea va ajunge direct la adresa destinatarului

Logare

Conectare la contul de utilizator Încă nu ai un cont Libristo? Crează acum!

 
obligatoriu
obligatoriu

Nu ai un cont? Beneficii cu contul Libristo!

Datorită contului Libristo, vei avea totul sub control.

Creare cont Libristo