Transport gratuit la punctele de livrare Pick Up peste 299 lei
Packeta 15 lei Easybox 20 lei Cargus 25 lei FAN 25 lei

Method For Simultaneous Estimation Of Glucosamine And Boswellic Acids

Limba englezăengleză
Carte Carte broșată
Carte Method For Simultaneous Estimation Of Glucosamine And Boswellic Acids Badmanaban Ramalingam
Codul Libristo: 15664917
Editura LAP Lambert Academic Publishing, decembrie 2016
Objective: The objective is to develop and validate simple, accurate, sensitive and rapid , HPTLC me... Descrierea completă
? points 86 b
192 lei -9 %
173 lei
În depozitul extern Expediem în 8-10 zile

30 de zile pentru retur bunuri


Ar putea de asemenea, să te intereseze


Feuchtgebiete Charlotte Roche / Carte broșată
common.buy 47 lei
Biodiesel Hayat Bennadji / Carte broșată
common.buy 468 lei
Mrs. Owen's Illinois cook book T. J. V. Owen / Carte broșată
common.buy 198 lei
Patriotic Favorites for Strings John Moss / Carte broșată
common.buy 54 lei
40 jahre Schauspieler Emil Thomas / Carte broșată
common.buy 300 lei
Literary landmarks of London Laurence Hutton / Carte broșată
common.buy 215 lei

Objective: The objective is to develop and validate simple, accurate, sensitive and rapid , HPTLC method for simultaneous estimation of Glucosamine (GLU) and ß-Boswellic acids (BAs) in their combined tablet dosage form. Experimental Work: In HPTLC method, chromatographic separation was carried out on TLC plate pre-coated with silica gel 60F254 using mobile phase-A,Toluene-Ethylacetate (2.5:1.5 v/v) for 11-KBA and A-11-KBA,scanning the plate at 260 nm [scan-1] and mobile phase-B, 1-Butanol -Water-Glacial acetic acid (3:1:1, v/v/v) for GLU ,derivatized the plate by Ninhydrin reagent and scanning the plate at 485 nm[scan-2]. Results: The HPTLC method was found to be linear over the range of 6250-31250 , 300-1500 and 150-750 ng/band for GLU,11-KBA and A-11-KBA , respectively.In this method, % RSD of assay determination of both drugs was found to be less than 2.0 and mean % recoveries were found between 98-101 %. Conclusion: The method was found to be precise as % RSD of assay in all cases was less than 2.0. High percentage recoveries obtained in this method indicate that the method is accurate. There was no interference from any excipients in the determination of drugs in tablets.

Informații despre carte

Titlu complet Method For Simultaneous Estimation Of Glucosamine And Boswellic Acids
Limba engleză
Legare Carte - Carte broșată
Data publicării 2016
Număr pagini 88
EAN 9783330015289
ISBN 3330015284
Codul Libristo 15664917
Greutatea 147
Dimensiuni 150 x 220 x 5
Dăruiește această carte chiar astăzi
Este foarte ușor
1 Adaugă cartea în coș și selectează Livrează ca un cadou 2 Îți vom trimite un voucher în schimb 3 Cartea va ajunge direct la adresa destinatarului

Logare

Conectare la contul de utilizator Încă nu ai un cont Libristo? Crează acum!

 
obligatoriu
obligatoriu

Nu ai un cont? Beneficii cu contul Libristo!

Datorită contului Libristo, vei avea totul sub control.

Creare cont Libristo