Transport gratuit la punctele de livrare Pick Up peste 299 lei
Packeta 15 lei Easybox 20 lei Cargus 25 lei FAN 25 lei

Impact of Films on the Long-Term Behavior of Stationary Electrical Connections and Contacts in Electric Power Systems

Limba englezăengleză
Carte Carte broșată
Carte Impact of Films on the Long-Term Behavior of Stationary Electrical Connections and Contacts in Electric Power Systems Sebastian Dreier
Codul Libristo: 10906102
Editura Tudpress Verlag Der Wissenschaften Gmbh, februarie 2016
Stationary electrical connections and contacts, such as power connections, are commonly applied in e... Descrierea completă
? points 150 b
303 lei
În depozitul extern Expediem în 14-18 zile

30 de zile pentru retur bunuri


Ar putea de asemenea, să te intereseze


Nachbehandlung d. VKB-Plastik Alfred Hochrein / Carte broșată
common.buy 318 lei
Battle of the Blanket Forts Marta Kissi / Copertă tare
common.buy 82 lei
Hungry for More: A Harem of Recipes Laura Greenwood / Carte broșată
common.buy 89 lei
"Tanks are Mighty Fine Things!" Wesley W Stout / Carte broșată
common.buy 65 lei
Il dinosauro di plastica Federico Scarioni / Carte broșată
common.buy 60 lei
La Matrice de Diffusion D Un Conduit Trait Mohamed Taktak / Carte broșată
common.buy 556 lei

Stationary electrical connections and contacts, such as power connections, are commonly applied in electric power systems used for generation, transmission and distribution of electric energy. Several different degradation mechanisms can increase the contact resistance and might therefore reduce the power connection's lifetime. The degradation by film development is often considered as a reason for contact failure. In this research work, the impact of film development produced by chemical reactions, such as oxidation, on the long-term behavior of stationary electrical connections and contacts was studied with crossed rods. Typical material systems for electric power systems were considered in this study: Cu-ETP bare, silver-, nickel- or tin-coated, Al99.5 and AlMgSi0.5. The initial contact resistance and the plastic deformed area of the considered material systems was measured in experimental tests. The film's impact was further determined through comparative experimental studies in air and inert gas. During the experimental tests on perpendicularly crossed rods, other degradation mechanisms were suppressed. The film's impact within the formation phase was studied in more detail. Moreover, the dependency on different environments was tested. Supplementary studies were performed at low forces as well as analytical assessment of the impact of radial and axial film growth on circular contact points. As result, a general description of the interactions between film development, time, material and temperature at circular contact points is presented in this book. An additional chapter considers the long-term behavior of power connections operated in areas with harsh environmental conditions. For over two and a half years, long-term field tests investigating bolted busbar joints were conducted in desert and tropical rainforest environments.

Informații despre carte

Titlu complet Impact of Films on the Long-Term Behavior of Stationary Electrical Connections and Contacts in Electric Power Systems
Limba engleză
Legare Carte - Carte broșată
Data publicării 2016
Număr pagini 174
EAN 9783959080378
ISBN 9783959080378
Codul Libristo 10906102
Greutatea 213
Dimensiuni 148 x 210 x 9
Dăruiește această carte chiar astăzi
Este foarte ușor
1 Adaugă cartea în coș și selectează Livrează ca un cadou 2 Îți vom trimite un voucher în schimb 3 Cartea va ajunge direct la adresa destinatarului

Logare

Conectare la contul de utilizator Încă nu ai un cont Libristo? Crează acum!

 
obligatoriu
obligatoriu

Nu ai un cont? Beneficii cu contul Libristo!

Datorită contului Libristo, vei avea totul sub control.

Creare cont Libristo