Transport gratuit la punctele de livrare Pick Up peste 299 lei
Packeta 15 lei Easybox 20 lei Cargus 25 lei FAN 25 lei

Evaluation and Implementation Guide for Current Groundwater Mass Flux Measurement Practices

Limba englezăengleză
Carte Carte broșată
Carte Evaluation and Implementation Guide for Current Groundwater Mass Flux Measurement Practices Jack Grierson Wheeldon
Codul Libristo: 08239624
Editura Biblioscholar, octombrie 2012
Contaminant mass flux is an important parameter needed for decision making at sites with contaminate... Descrierea completă
? points 157 b
317 lei
În depozitul extern Expediem în 14-18 zile

30 de zile pentru retur bunuri


Ar putea de asemenea, să te intereseze


Contaminant mass flux is an important parameter needed for decision making at sites with contaminated groundwater. New and potentially better methods for measuring mass flux are emerging. This study looks at the conventional transect method (TM), and the newer passive flux meter (PFM), modified integral pump test (MIPT), and tandem circulating well (TCW) methods. In order to facilitate transfer and application of these innovative technologies, it is essential that potential technology users have access to credible information that addresses technology capabilities, limitations, and costs. This study provides such information on each of the methods by reviewing implementation practices and comparing the costs of applying the methods at 16 standardized "template" sites. The results of the analysis are consolidated into a decision tree that can be used to determine which measurement method would be most effective, from cost and performance standpoints, in meeting management objectives at a given site. The study found that, in general: (1) the point methods (i.e. the TM and PFM) were less expensive to use to characterize smaller areas of contamination while the pumping methods (the MIPT and TCW) would be more economical for larger areas, (2) the pumping methods are not capable of high resolution sampling, which may be required to characterize heterogeneous systems or to design remediations, and (3) when high resolution is required, the PFM is more economical then the TM. Finally, the study demonstrated that, arguably, test results of the newer methods indicate that their accuracy is as good as, or better than, the accuracy of the TM, the currently accepted method.

Informații despre carte

Titlu complet Evaluation and Implementation Guide for Current Groundwater Mass Flux Measurement Practices
Limba engleză
Legare Carte - Carte broșată
Data publicării 2012
Număr pagini 124
EAN 9781288228621
ISBN 9781288228621
Codul Libristo 08239624
Editura Biblioscholar
Greutatea 236
Dimensiuni 189 x 246 x 7
Dăruiește această carte chiar astăzi
Este foarte ușor
1 Adaugă cartea în coș și selectează Livrează ca un cadou 2 Îți vom trimite un voucher în schimb 3 Cartea va ajunge direct la adresa destinatarului

Logare

Conectare la contul de utilizator Încă nu ai un cont Libristo? Crează acum!

 
obligatoriu
obligatoriu

Nu ai un cont? Beneficii cu contul Libristo!

Datorită contului Libristo, vei avea totul sub control.

Creare cont Libristo