Electrical Resistivity subsurface survey

Limba englezăengleză
Carte Carte broșată
Carte Electrical Resistivity subsurface survey Nafiu Sadq Aliyu
Codul Libristo: 02201456
Editura LAP Lambert Academic Publishing, octombrie 2013
The type of method adopted for this research was 1D electrical resistivity, using the Geopulse Tarra... Descrierea completă
? points 131 b
291 lei -9 %
263 lei
În depozitul extern Expediem în 8-10 zile

30 de zile pentru retur bunuri


Ar putea de asemenea, să te intereseze


Ein neuer Anfang Esther Hicks / Carte broșată
common.buy 52 lei
Kenneth Boulding Robert Scott / Copertă tare
common.buy 640 lei
Plantagenet Empire 1154-1224 Martin Aurell / Carte broșată
common.buy 329 lei
Preguem de la A a la Z Juanjo Fernández Sola / Carte broșată
common.buy 67 lei
Salam Mirjam Michael Landgraf / Copertă tare
common.buy 87 lei
Kaite Woo: The Best Club Fran Manushkin / Carte broșată
common.buy 40 lei
Lena Roswitha Gruber / Copertă tare
common.buy 87 lei
Beethovens Briefe Karl Storck / Carte broșată
common.buy 180 lei
Modern Electrical Drives H. Bülent Ertan / Carte broșată
common.buy 1.901 lei
Fashhion-Plus Knits LEISURE ARTS / Carte broșată
common.buy 54 lei
Audience Transformations Nico Carpentier / Copertă tare
common.buy 1.000 lei
Florante Francisco Balagtas / Copertă tare
common.buy 252 lei

The type of method adopted for this research was 1D electrical resistivity, using the Geopulse Tarrameter. A schlumberger configuration was carried out to map out the geological features of the Earth subsurface. Five profiles were carried out in the study area, each profile, the layout geometry for the electrical survey were the normal schlumberger arrays. The maximum current electrode seperation (AB) was 200m i.e AB/2=100m. Based on the electrical resistivity value obtained in the study area, the following deduction were made: The average depth to the fresh basement is generally beyond 30m, the study revealed the presence of two distinct layers, the top soil and weathered basement with resistivity range of 20-782 ohm-meter and 100-978ohm-meter respectively. The overburden with a thickness of 18m and this is a good aquifer in the study area.

Informații despre carte

Titlu complet Electrical Resistivity subsurface survey
Limba engleză
Legare Carte - Carte broșată
Data publicării 2013
Număr pagini 96
EAN 9783659431746
Codul Libristo 02201456
Greutatea 161
Dimensiuni 150 x 220 x 6
Dăruiește această carte chiar astăzi
Este foarte ușor
1 Adaugă cartea în coș și selectează Livrează ca un cadou 2 Îți vom trimite un voucher în schimb 3 Cartea va ajunge direct la adresa destinatarului

Logare

Conectare la contul de utilizator Încă nu ai un cont Libristo? Crează acum!

 
obligatoriu
obligatoriu

Nu ai un cont? Beneficii cu contul Libristo!

Datorită contului Libristo, vei avea totul sub control.

Creare cont Libristo