Master's Thesis from the year 2013 in the subject Engineering - Power Engineering, grade: none, - (F... Descrierea completă
? points 210 b
425 lei
În depozitul extern Expediem în 14-18 zile

30 de zile pentru retur bunuri


Ar putea de asemenea, să te intereseze


Auxology Michael Hermanussen / Copertă tare
common.buy 190 lei
Creative Haven WinterScapes Coloring Book Jessica Mazurkiewicz / Carte broșată
common.buy 37 lei
curând
Clinical Infertility and In Vitro Fertilization Botros R. M. B. Rizk / Copertă tare
common.buy 1.301 lei
Binnen der rothen Tonne Heinrich Smidt / Carte broșată
common.buy 160 lei
American Theater in the Culture of the Cold War Bruce A. McConachie / Copertă tare
common.buy 328 lei
Circuitous Journeys David J. Leigh / Copertă tare
common.buy 455 lei
Tragverhalten von Stahl-Glas-Verbundkonstruktionen Georg Terfloth / Carte broșată
common.buy 1.297 lei
Hammurabi's Laws MEJ Richardson / Carte broșată
common.buy 706 lei
Armenian Question in the Caucasus Tale Heydarov / Copertă tare
common.buy 497 lei
Bridging the Border Rodolfo O. De la Garza / Carte broșată
common.buy 337 lei
Merriweather Girls and the Mystery of the Queen's Fan Lizette M. Edholm / Carte broșată
common.buy 161 lei
... und fahr'n wir ohne Wiederkehr Fritz Blankenhorn / Carte broșată
common.buy 52 lei
Alterspyramide und soziales Systeme Theresa Hiepe / Carte broșată
common.buy 201 lei
Der dritte Mann im Ring Arthur Mercante / Copertă tare
common.buy 164 lei

Master's Thesis from the year 2013 in the subject Engineering - Power Engineering, grade: none, - (Faculty of engineering-Minia university - Electrical engineering department), course: Electrical engineering (Renewable energy), language: English, abstract: Wind electrical power systems are recently getting lot of attention, becausethey are cost competitive, environmental clean and safe renewable powersource, as compared with fossil fuel and nuclear power generation. A specialtype of induction generator, called a doubly fed induction generator (DFIG),is used extensively for high-power wind applications. They are used moreand more in wind turbine applications due to ease controllability, highenergy efficiency and improved power quality.This thesis aims to develop a method of a field orientation scheme forcontrol both the active and reactive powers of a DFIG driven by a windturbine.The proposed control system consists of a wind turbine that drives aDFIG connected to the utility grid through AC-DC-AC link. The maincontrol objective is to regulate the dc link voltage for operation at maximumavailable wind power.This is achieved by controlling the and axescomponents of voltages and currents for both rotor side and line sideconverters using PI controllers. The complete dynamic model of theproposed system is described in detail. Computer simulations have beencarried out in order to validate the effectiveness of the proposed systemduring the variation of wind speed. The results prove that , better overallperformances are achieved, quick recover from wind speed disturbances inaddition to good tracking ability.Generally, any abnormalities associated with grid asymmetrical faults aregoing to affect the system performance considerably. During grid faults,unbalanced currents cause negative effects like overheating problems andmechanical stress due to high torque pulsations that can damage the rotor shaft, gearbox or blade assembly. Therefore, the dynamic model of theDFIG, driven by a wind turbine during grid faults has been analyzed anddeveloped using the method of symmetrical components. The dynamicperformance of the DFIG during unbalanced grid conditions is analyzed anddescribed in detail using digital simulations.A novel fault ride-through (FRT) capability is proposed (i.e. the ability ofthe power system to remain connected to the grid during faults) with suitablecontrol strategy in this thesis. In this scheme, the input mechanical energy ofthe wind turbine during grid faults is stored and utilized at the moment offault clearance, instead of being dissipated in the resistors of the crowbarcircuit as in the existing FRT schemes. [...]

Informații despre carte

Titlu complet Control of a Wind Driven Doubly Fed Induction Generator During Grid Faults
Limba engleză
Legare Carte - Carte broșată
Data publicării 2013
Număr pagini 140
EAN 9783656368380
ISBN 3656368384
Codul Libristo 05283714
Editura Grin Publishing
Greutatea 191
Dimensiuni 148 x 210 x 8
Dăruiește această carte chiar astăzi
Este foarte ușor
1 Adaugă cartea în coș și selectează Livrează ca un cadou 2 Îți vom trimite un voucher în schimb 3 Cartea va ajunge direct la adresa destinatarului

Logare

Conectare la contul de utilizator Încă nu ai un cont Libristo? Crează acum!

 
obligatoriu
obligatoriu

Nu ai un cont? Beneficii cu contul Libristo!

Datorită contului Libristo, vei avea totul sub control.

Creare cont Libristo