Transport gratuit la punctele de livrare Pick Up peste 299 lei
Packeta 15 lei Easybox 20 lei Cargus 25 lei FAN 25 lei

Balancing Exhaust Ventilation Systems

Limba englezăengleză
Carte Carte broșată
Carte Balancing Exhaust Ventilation Systems Vivek Balasubramanian
Codul Libristo: 06820851
Editura VDM Verlag Dr. Müller, noiembrie 2008
Dampers are used to adjust the distribution of §airflows in duct systems. The common (i.e., most §c... Descrierea completă
? points 124 b
263 lei -4 %
250 lei
La editor doar la comandă Expediem în 3-5 zile

30 de zile pentru retur bunuri


Ar putea de asemenea, să te intereseze


Hot Vegan Robin Robertson / Carte broșată
common.buy 81 lei
In absentia [Judici a la Terra] Jordi Ortiz / Carte broșată
common.buy 59 lei
Thirteen Albatrosses DONALD HARINGTON / Carte broșată
common.buy 81 lei
Industrial Power Systems Sheeba Khan / Copertă tare
common.buy 1.465 lei
Sound Pulses F. G. Friedlander / Carte broșată
common.buy 242 lei
Absurdist Angles on History Merritt Abrash / Carte broșată
common.buy 97 lei
Affine Ebenen Artur Bergmann / Carte broșată
common.buy 681 lei

Dampers are used to adjust the distribution of §airflows in duct systems. The common (i.e., most §commonly used) method is to adjust each damper in §turn so that the airflow through its branch equals §the desired level. Typically, the airflow through §each branch duct is estimated from the centerline §velocity pressure. To test the effectiveness of that §approach, dampers were adjusted on a seven branch, §full-sized experimental duct system. After adjusting §the dampers for a given condition, the percent §excess airflow (%Qexcess) for the system was §estimated as the amount above the ideal fan airflow §that would exist if the fan speed were adjusted so §that the lowest ratio of airflow to airflow goal for §any branch was unity. The lower the value of percent §excess airflow, the more perfectly balanced the §system was. The results varied with the level of the §target airflows. The excess airflow values were much §higher than the airflow values found by Dodrill §(2004) on the same system for the SPh Goal Ratio §method proposed by Guffey (2005). This analysis §should be useful to professionals in the fields of §HVAC and ventilation design.

Informații despre carte

Titlu complet Balancing Exhaust Ventilation Systems
Limba engleză
Legare Carte - Carte broșată
Data publicării 2009
Număr pagini 72
EAN 9783639120301
Codul Libristo 06820851
Greutatea 124
Dimensiuni 150 x 220 x 4
Dăruiește această carte chiar astăzi
Este foarte ușor
1 Adaugă cartea în coș și selectează Livrează ca un cadou 2 Îți vom trimite un voucher în schimb 3 Cartea va ajunge direct la adresa destinatarului

Logare

Conectare la contul de utilizator Încă nu ai un cont Libristo? Crează acum!

 
obligatoriu
obligatoriu

Nu ai un cont? Beneficii cu contul Libristo!

Datorită contului Libristo, vei avea totul sub control.

Creare cont Libristo